642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC
Solicitation (Request for proposal) from 244-Network Contract Office 4 (36c244). This notice has closed.
Service-disabled veteran-owned (SDVOSB)Reserved for small firms owned and run by service-disabled veterans.Who qualifies
- ClosedDays left to respond
- 23 daysThis buyer usually gives
- 34%Notices this buyer changes
- $2.6MTypical award from this office
What BidCamel found about this buyer
- This office usually gives bidders 23 days to respond; this notice gives 141 days.
- It changed 34% of its 50 notices after posting, so check for amendments before you submit.
- It has 8 open bids right now. See them all.
- It has made 8 awards in our records, typically $2.6M.
Companies this office paid before
- Gc Joint Venture Essex: 2 awards, $7.8M total
- Serviam Construction Llc: 1 award, $26.0M total
- L-J-L Trucking, Inc: 1 award, $17.2M total
- Ce Solution Plus Corp.: 1 award, $1.2M total
- Nuclear Diagnostic Products of Philadelphia, Inc: 1 award, $1.2M total
These are past winners at this office, not the winner of this exact contract.
Key details
- Solicitation number
- 36C24426R0088
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Size standard for this code
- 45 million dollars in average annual revenue
- Set-aside
- Service-disabled veteran-owned (SDVOSB)
- Buying
- Service
- Place
- PA · Pennsylvania bids
- Posted
- Jul 2, 2026
- Last changed
- Oct 27, 2026 (7 versions)
- Contact
- Contact details are on the SAM.gov notice. Open on SAM.gov
Description
642-22-104, 36C24426R0088, Upgrade Substation Building 2, Phase 1, PHL CMCVAMC Proposal Due Date: 11/20/2026 at 4:00pm EST. Email proposals to Kevin Rodgers at [email protected]. Corporal Michael J. Crescenz Medical Center (CMC VAMC) requires replacement of Electrical Substations 1 and 2 in order to increase electrical capacity to support future facility projects. The existing substations are approximately 29 years old and require replacement to support current and future electrical demands. This project will replace Electrical Substations 1 and 2 with new 480/277V substations each containing a 1500 kVA transformer. A temporary 480/277V substation with a 1500 kVA transformer shall be installed to maintain electrical service to the facility during demolition and construction activities. Upon completion of construction, the temporary substation shall remain installed as a spare substation for the facility. All work shall be phased to minimize service outages and maintain continuous operation of the medical center. Defined and issued bid documents (drawings and specifications) will serve as the basis of this construction project.
Similar open bids
1 day leftNov 20, 2026
654-24-004 | Remediate Old Parking Garage
261-NETWORK Contract Office 21 (36C261)
Solicitation
1 day leftNov 20, 2026
Rehab Kiosk Restrooms, NPS-ORCA
National Park Service Contracting Activity
Small businessSolicitation
1 day leftNov 21, 2026
SOLICITATION NOTICE- Massena NY Virtual Law Enforcement Training Facility- Construction
Pbs Project Delivery East - Branch C
Small businessSolicitation
3 days leftNov 22, 2026
D/B UFC Intermediate Logistics Maintenance Center (ILMC), Buliluyan Port, Palawan, Philippines
Navfacsyscom Far East
Presolicitation
3 days leftNov 23, 2026
Gis lab maun botswana
W2SD Endist Europe
Presolicitation
From SAM.gov and USAspending.gov public data. BidCamel adds the buyer and award facts.