Kitchen Exhaust Cleaning, Kitchen Fire Suppression System Service, and Portable Fire Extinguisher Service
Sources Sought (Request for quotation) from 256-Network Contract Office 16 (36c256). This notice has closed.
- ClosedDays left to respond
- 15 daysThis buyer usually gives
- 13%Notices this buyer changes
- $688KTypical award from this office
What BidCamel found about this buyer
- This office usually gives bidders 15 days to respond; this notice gives 15 days.
- It changed 13% of its 75 notices after posting, so check for amendments before you submit.
- It has 13 open bids right now. See them all.
- It has made 23 awards in our records, typically $688K.
Companies this office paid before
- Servexo, Inc.: 3 awards, $2.5M total
- Nextera Energy Services Gas, Llc: 3 awards, $2.1M total
- Wolverton Property Management, Inc: 2 awards, $4.9M total
- Mississippi Power Co: 2 awards, $2.9M total
- Coactint Llc: 2 awards, $797K total
These are past winners at this office, not the winner of this exact contract.
Key details
- Solicitation number
- 36C25627Q0131
- NAICS code
- 811310 Commercial and Industrial Machinery and Equipment
- Size standard for this code
- 12.5 million dollars in average annual revenue
- Set-aside
- Open to all (no set-aside)
- Buying
- Service
- Place
- North Little Rock · Mississippi bids
- Posted
- Nov 5, 2026
- Last changed
- Nov 5, 2026
- Contact
- Contact details are on the SAM.gov notice. Open on SAM.gov
Description
1. Title: Kitchen Exhaust Cleaning, Kitchen Fire Suppression System Service, and Portable Fire Extinguisher Service 2. Background: Per NFPA 96, the new Food Services Center (Bldg. 211), and JLM dietetics are required to have their kitchen hoods cleaned semiannually due to limited grease use and/or limited meal service. The hoods for JLM, B170, and 202 require quarterly cleaning due to the heavy grease operations. During regular cleaning, the hood system must be inspected, tested and maintained. Per NFPA and regulatory requirements, kitchen fire suppression systems shall be inspected and serviced at a minimum of every 6 months to ensure proper operation and life safety compliance. Given that the kitchen fire suppression systems will be inspected, government is including the inspection, testing and maintenance of the portable fire extinguisher. Per NFPA and regulatory requirements, portable fire extinguishers shall be inspected, serviced, and hydrotested to ensure proper operation. 3. Purpose: The Network Contracting Office (NCO) 16, located at Galleria Financial Center, 5075 Westheimer Rd, Ste 750, Houston, TX 77030, hereby issues the following Sources Sought to Request Information (RFI) with the intent of determining the contractor interest, capabilities, qualifications of potential businesses and estimated industry pricing information for market research and estimated budgetary purpose for Kitchen Exhaust Cleaning, Kitchen Fire Suppression System Service, and Portable Fire Extinguisher Service 4. Requirement summary: The Government presently considers fire-protection equipment inspection, testing, preventive maintenance, recharge, hydrostatic testing, repair, authorized replacement, and restoration to be the predominant purpose of the integrated requirement. Accordingly, North American Industry Classification System code 811310 is proposed. The anticipated requirement combines recurring commercial services at the John L. McClellan Memorial Veterans Hospital in Little Rock and the Eugene J. Towbin Healthcare Center in North Little Rock. The draft scope includes: Quarterly and semiannual cleaning of identified commercial kitchen hoods, plenums, ducts, fans, dampers, and related exhaust-system components. Semiannual inspection, testing, maintenance, tagging, and documentation for 10 wet-chemical kitchen fire suppression systems. Inspection, maintenance, recharge, hydrostatic testing, repair, authorized replacement, pickup, return, tagging, and asset-level reporting for approximately 948 portable fire extinguishers across listed classes and locations. Qualified personnel, manufacturer authorization when required, calibrated test equipment, safety controls, chemical and waste management, impairment coordination, incident reporting support, and digital service records. A potential base period with four one-year option periods. The final contract structure and quantities have not been determined. Respondents should address the ability to perform all three principal service areas as the prime contractor and identify any anticipated subcontracting or teaming arrangement. 5. Requested capability information: Interested parties should submit a concise capability statement, preferably no more than 10 pages excluding cover page and supporting certifications. Clearly identify proprietary information. Address each item below in the order listed. Legal business name, physical address, website, and primary point of contact, including name, title, telephone number, and email address. Unique Entity Identifier and Commercial and Government Entity code. Business size under proposed North American Industry Classification System code 811310 and any recommended alternative code. Socioeconomic status, including small business, veteran-owned small business, service-disabled veteran-owned small business, women-owned small business, economically disadvantaged women-owned small business, Historically Underutilized Business Zone small business, 8(a) participant, or small disadvantaged business. Identify current Small Business Administration VetCert status when claiming veteran-owned or service-disabled veteran-owned status. Whether the respondent intends to perform as the prime contractor and the approximate percentage of work the respondent expects to perform with its own employees. Capability to provide all required service areas at both campuses, including after-hours kitchen exhaust cleaning and normal-business-hours fire protection services. Current qualifications and certifications relevant to National Fire Protection Association Standards 10, 17A, and 96; Underwriters Laboratories 300-listed systems; Ansul and PyroChem systems; kitchen exhaust cleaning; extinguisher maintenance; and hydrostatic testing. Identify whether credentials are held by the respondent or a proposed subcontractor. At least two recent and relevant contracts or projects completed within the past five years. Include customer, contract or project identifier if releasable, period of performance, dollar magnitude or range, scope, locations, and customer point of contact if authorized. Available staffing, mobilization timeframe, service radius, emergency or impairment response capability, and ability to maintain recurring schedules at both campuses. Quality-control approach, asset tracking, service-report format, deficiency management, chain-of-custody controls, and ability to provide searchable Microsoft Excel or Portable Document Format reports. Any contract vehicle available to the Government, including Federal Supply Schedule contract information, if applicable. 6. Licenses, certifications, and technical qualifications: Respondents shall identify the licenses, certifications, manufacturer authorizations, and technical qualifications currently available to perform the draft requirement. A credential matrix is acceptable at the Sources Sought stage. Do not submit Social Security numbers, dates of birth, home addresses,…
Similar open bids
5 days leftNov 24, 2026
Danobat Spherical Grinder PM
Pearl Harbor Naval Shipyard Imf
Presolicitation
6 days leftNov 25, 2026
USCG IPD Cape May Crane Repairs
Base Portsmouth
Small businessSolicitation
7 days leftNov 26, 2026
Eaton Powerware System Replacement
241-NETWORK Contract Office 01 (36C241)
Veteran-ownedCombined Synopsis/Solicitation
7 days leftNov 27, 2026
FY 27 Fire Department Trainer Maintenance & Winterization/De-Winterization
FA4528 5 Cons
Small businessSolicitation
8 days leftNov 28, 2026
Service Repair for Sciaky Spot Welder
FA8125 Afsc Pzima
Solicitation
From SAM.gov and USAspending.gov public data. BidCamel adds the buyer and award facts.